As the LPTIM counter can run out of a clock which is asynchronous to the APB bus clock, it may be tricky to read it out. Upon active clock edge, the LPTIM counter starts to change, increment, and it takes time until it settles with the new incremented value. Duration of this process can be estimated from the maximum LPTIM clock frequency. After that, the value of the counter is stable until the next clock edge.
When the LPTIM counter is read out, due to its clock being asynchronous to APB clock it may happen, that at the moment of sampling its value the counter has not been settled yet. Some bits may contain the old value from before the increment, other bits the new value after the increment. As there's no way of telling whether the read out value was such unstable thus invalid value, the usual procedure is reading the counter twice until the two readouts match each other.
However, reading out the counter twice takes a couple of APB (and thus system clock) cycles. For such process to succeed, the time while the counter is stable between its clock's edges must be somewhat longer than just a couple of APB clocks. This limits the LPTIM kernel clock frequency to a fraction of the APB/system clock frequency in cases, when the LPTIM counter has to be read out while running.
Of course, there are LPTIM applications where there's no need to read out the counter, and there no such limitation applies.