As the incrementing ripple process of the asynchronous counter of LPTIM starts at the active edge of its clock, shorty after this clock its value is unstable and changing. It's so then logical, that the comparison events (both LPTIM_CNT==LPTIM_ARR, and LPTIM_CNT==LPTIM_CMP) take place at that clock edge, just before the increments starts (possibly from a slightly delayed version of the clock). In other words, the comparison happens with what the value of counter was at the end of the previous cycle; and if the LPTIM clock is much slower than its maximum possible clock, that was also the value of the counter during most of the previous cycle.
As a consequence, in cases when counter readout is possible (especially with LPTIM clock significantly slower than APB clock), the counter value read out immediately after a comparison event (e.g. in the autoreload/compare-match interrupt) is not equal to LPTIM_ARR/LPTIM_CMP; rather, it's 0/LPTIM_CMP+1.
While this is expected and consistent with the "normal" timers' behaviour, sometimes this fact surprises the users.