One of the basic features of LPTIM is the Compare, which allows to operate a PWM output, and/or an interrupt to implement various timing schemes.
While the narrative in RM says, that the Compare event (thus interrupt) occurs when CNT matches CMP, the observed behaviour indicates a different behaviour.
Namely, the Compare event occurs, when the comparison between CNT and CMP changes from CNT
When LPTIM is used in the "conventional" way, i.e by setting CMP once and just expecting it to trigger Compare interrupt once per LPTIM period, the behaviour of this mechanism is exactly the same as if the Compare interrupt would indeed trigger at CNT=CMP. The difference demonstrates itself, when CMP is changed from value above CNT to value below CNT - in that case, due to the described mechanism, interrupt is fired immediately, not "waiting" until the match.
This makes it difficult to use LPTIM for a "walking timeout", where the counter is left to run freely and if an event requires a timeout, the occurence of next interrupt is calculated from the current CNT value. If the previous value of CMP was above CNT and the next calculated CMP value wraps around to below CNT, the interrupt is surprisingly fired immediately.