291. In Up-Down (Center-Aligned) mode, Update interval is shorter than in plain Up or Down mode
In STM32, Timer in up-down (center-aligned) mode generates Update event (and sets TIMx_SR.UIF, resulting in interrupt if enabled by TIMx_DIER.UIE, or triggering DMA if enabled by TIMx_DIER.UDE) twice per total timer period: once when finishing the up-run, and second time, when finishing the down-run.
However, contrary to pure up or down running Timer, where the period between Updates is (ARR + 1) prescaled clock cycles, in up-down mode the period between Updates is ARR prescaled clock cycles.
The reason is, that the counter does not dwell twice at the endpoints (0 and ARR). The total period of Timer is then given by two of such events/interrupts, as has already been discussed in g290.
See also g292