The LSE crystal oscillator, with a typically 32.768kHz crystal, is the usual clock source for RTC (Real Time Clock) module. As LSE is in the backup-power-domain, intended to be powered from a battery through the VBAT pin, when VDD is unavailable, it is designed to be an ultra-low power circuit, consuming as little power as possible.
This however also means, that this circuit can be easily influenced by external interference. It is therefore vital to design the LSE circuitry and associated PCB layout so, that the the surroundings of this circuit is as electrically quiet as possible, making their tracks as short as possible, returning ground from the burden capacitors to VSS pin closest to oscillator pins via dedicated tracks separate from other ground tracks/planes, and possibly shielding the LSE conductors by enclosing them into a ground ring. These guidelines, together with example layout and recommendations for parts selection are described in AN2867.
Some users are surprised by the time it takes the LSE to start up, after the VBAT domain has been powered down. This startup time can't be guaranteed by ST, as it depends on the particular details of the design (additionally, it may also depend on LSE "drive" setting in RCC_BDCR in the newer STM32 models). Counterintuitively, good design may result in long startup time, as LSE - similarly to all other crystal and other oscillators - starts up by picking up noise, and filtering and amplifying it. However, this implication can't be reversed: long startup time does not indicate it's a good LSE design,
So, software has to take into account, that LSE can start for seconds. 5 seconds or more is not an unusual LSE startup time, as for example Bob S explains in this thread.
In the last years, price of external 32.768kHz oscillators (many of them MEMS-based) has dropped to the point, where they are a viable option for LSE clock source in many, but the most cost sensitive designs. This is one way how to significantly decrease or entirely avoid sensitivity of the LSE precision on surrounding circuit/signals/currents, and also the startup time may be guaranteed by the oscillator's manufacturer to be significantly shorter.