STM32 gotchas
304. LSE does not reach some peripherals due to LSESYSEN switch in newer STM32

The primary role of the LSE oscillator is to provide a precise 32.768kHz clock to the RTC to maintain real time. It is in the VBAT/backup power domain and it will run in all low-power modes, including the VBAT mode.

In newer STM32, there's an increasing number of peripherals which are capable of running in low-power modes (although not in VBAT mode), which benefit from being clocked from such a precise clock source as LSE. This includes not only the dedicated low-power LPTIM and LPUART, but also standard timers and UARTs.

On the other hand, fanning out LSE to that many points also means increased load on the LSE and thus increased current consumption. In applications where low consumption is crucial, this would mean a disadvantage compared to older STM32 families. Therefore, in the newest STM32 low-power families - such as the 'L5, 'U0, 'U5 - all peripherals except RTC (and TAMP) have the LSE clock available only if it has been enabled using a switch controlled by the RCC_BDCR.LSESYSEN bit.